Automatic Capsule Filling Machine

ACF-140 Automatic Capsule Filling Machine

  • Fills the powders that running un-smoothly.
  • Better Accuracy, Average output around 100,000 capsules per hour.
  • Easier Operation.
  • Lower Maintenance.
  • The machine conforms to cGMP standards.
  • Electric control system conforms to UL,CE standards.

Machine identity :

  1. Tamping filling, get better accuracy and more average weight.
  2. Vacuum pump using German made dry pump, oil free to gain the usage of the pump, it also easy to clean and maintaining.
  3. Filling weight adjustable.
  4. Additional large filter to gain the filter effect making the longer usage of pump and little maintaining, cleaning.
  5. Fills the powders that running un-smoothly, such as Ganoderma Lucidum, pollen, and royal jelly etc.
  6. Good quality, easy maintaining and operation.
  7. IQ/OQ documents are available.

Automatic Capsule Filling Machine is described station by station:

  • Empty gelatin capsules are fed from a storage hopper to the rectifier, and inserted with the aid of vacuum into one of the 10 sets of carrier segments each carrier segment holds 18 empty capsules.
  • The carrier segment's upper holder holding the caps is now lifted separation of cap and body is assisted by vacuum
  • The upper holder starts retracting while the lower proceeds to the dosing station.
  • Complete retraction of the upper holder is done at this station
  • Powder slug is inserted into the capsule body; when there is no capsule body held at the lower holder, the powder slug will be further pushed downward and collected in a receiver tray
  • Ejection of un-separated capsule or the up-side-down capsule caps is performed with an aid of upward stroking rods
  • Upper holder starts moving outward to the position above the lower holder
  • At this station, while upper and lower holders are closely matched the capsule bodies are pushed upward into the caps by steel rods
  • Now the closed capsules arriving at this station are again pushed upward by the other steel rods and leave the carrier segment
  • Carrier segment is vacuum-cleaned and proceeds to the capsule insertion station
Dosing disk level adjusting switch.

Technical Data

Model no.
ACF-140
Capacity (caps/hr)
80,000 ~ 100,000
Capsule Size
#00, #0, #1 ~ #4
Power Supply
220/380 V, 3 Phase, 50/60 Hz
Power Consumption
20.6 A
Main drive
3 HP
Auger drice
1/2 HP
Vacuum Pump
2 HP
De-duster
3 HP*2 PCS
Machine Weight
1,530 KGs
Dimension
1,180×1,390×2,092 mm (L×W×H)
Flaw capsule rejection station
Filling Chamber
Vacuum de-dusting
Capsule Joining Station